RA2300MKII System (Discontinued)
See RA3100
The RA3100 is the successor to the discontinued RA2300MKII. The RA3100 offers advanced capabilities with higher sampling speed than the RA2300MKII.
See RA3100
The RA3100 is the successor to the discontinued RA2300MKII. The RA3100 offers advanced capabilities with higher sampling speed than the RA2300MKII.
• Excellent vibration resistance
• Designed for embedding and installation
• Strong rugged handle makes carrying easy
• Control panel prevents dust interference
• Anti-noise protection in strong magnetic fields
• Ideal for constructing systems that isolate the power supply and account for differences in ground potential
• Proven in many industries: railroad, aerospace, construction, civil engineering, steel, and more
• Easy setup and confirmation
• Physical buttons for essential functions
• Configure detailed settings with touch panel
• Customizable realistic pen recorder mode
• Waveform display always available
Easy to operate and capture data, the Omniace RA2300MKII is a data acquisition system with a large dynamic waveform display and built-in printer for R&D and field use. Equipped with a variety of measurement modes, including long-term recording on a 160 GB hard disk (HD) or 256 GB industrial solid state drive (SSD) and a memory mode capable of capturing high-speed phenomena with excellent reliability, the RA2300MKII is the direct replacement to the RA2300A and Soltec TA220-2300.
Easy to operate and capture data, the Omniace RA2300MKII is a data acquisition system with a large dynamic waveform display and built-in printer for R&D and field use. Equipped with a variety of measurement modes, including long-term recording on a 160 GB hard disk (HD) or 256 GB industrial solid state drive (SSD) and a memory mode capable of capturing high-speed phenomena with excellent reliability, the RA2300MKII is the direct replacement to the RA2300A and Soltec TA220-2300.
Dynamic waveform display
12.1 inch LCD dynamically displays waveforms across 16 channels. Numerical display and waveform division can be configured by application.
Enhanced usability
Shorten setup time with virtual amplifier setup screen and AUTO button
Direct input sensors
Directly input voltage, strain, temperature, vibration, pressure or rotational pulse signal with 11 types sensors inherited from the RA1000 and RA2000 series.
Pen Recorder Mode
Pen recorder mode is used to output data to chart paper directly. This mode shows pen-written waveforms on the screen. Amplifiers and chart speed can be set similar to a chart recorder.
HD Recorder Mode
HD recorder mode saves data to a 160 GB HD or 256 GB SSD for long term storage. One microsecond sampling is possible when only 1 channel is used. When all 16 channels are used data can be recorded every 10 µs.
Continuous recording
Data is recorded to two gigabyte chunks. When more than two gigabytes is recorded another chunk is created and recording continues. Previously recorded data can be viewed during measurement. Moreover, this also limits damage caused by file corruption caused by power outages, etc. during recording.
Sample data and peak data
The Omniace is a digital recorder that converts analog input signals for storage as digital data. Error is introduced to the recorded data due to the relationship between the speed of this AD conversion and the frequency component of the input signal.
When the Omniace records an input signal, it is possible to record high frequency noise independent of the print speed. Additionally with the HD recorder, data can be stored to a hard disk for analysis.
Sample data
With this method, raw data is faithfully recorded at the designated recording speed (every 10 ms in this example).
Peak Data
Sampling is performed at the maximum sampling speed over the set recording interval (10 ms in the example) and the maximum and minimum values are recorded. This allows compression of data without losing peak values. However, peak data requires twice the recording capacity of the sample data method.
Data Looping
Data can be looped endlessly when recording over uncertain timeframes with unpredictable anomalies. With this function the most recent data is always stored to the hard drive.
Reduce Recording Paper Costs
Two gigabytes can hold two-hundred and nine 30 m recording paper rolls.
Memory Recorder
Record data at high speeds (up to 1μs) to internal memory (2 mW/ch). Memory from unused channels can be used for up to 32mW recording on one channel. Additionally, various measurement conditions can be set with trigger functions.
Data input to memory can be output to recording paper or other storage device.
Multi-Recorder Mode
Multi-recorder mode enables simultaneous recording to paper output, hard drive and memory. It is possible to record sudden phenomenon to the memory while recording on the chart paper or to the HDD or SSD.
X-Y Recorder
This mode records input signals from selected channels on an X-Y chart (X-axis: 1 channel, Y-axis: 3 channels). Output can be printed to chart paper at high resolution (1600 dot x 1600 dot).
Search large amounts of data quickly
The RA2300 MKII is equipped with functions to search large amounts of data quickly.
Thumbnail Bar
The waveform image of the recorded data for one selected channel can be displayed on the thumbnail bar. This data is easy to read and can be expanded by touching the point you want to see in greater detail.
Jump Search
The four methods below can be used to search data.
Numeric Display of Waveforms
Scale, signal name, numerical value and/or time interval can be displayed for waveforms between the 2 cursors on the replay monitor.
Shutdown
Memory data and measurement conditions are automatically saved to the hard drive when the device is turned off. This information is
automatically loaded from the hard drive the next time the device is started so measurement can begin with the same settings.
Easy setup
Up to 4 measurement conditions can be saved. Measurement conditions can be saved for each test, eliminating the need to make complicated configurations each time.
Timer
Automated measurements are performed at specified times and intervals.
CSV file conversion
The RA2300MKII can output files in CSV format for processing measurement data with spreadsheet or analysis software. It is equipped with functions to reduce measurement data size or convert large amounts of measurement data at once.
PC connection
The RA2300 can be controlled remotely via Ethernet connection to a PC. You can use Unifizer NS3300 (optional software) to record data, configure settings and start recording.
Sharing files with a PC
File sharing with a PC via Ethernet is possible. You can transfer the recorded data to your PC.
High-capacity data storage
File sharing with a PC via Ethernet is possible. You can transfer the recorded data from your PC.
Measures against power failure during long-term recording
When the RS2300MKII is connected to an uninterruptible power supply (UPS), the shutdown procedure will be performed automatically during a power failure. If a power outage occurs during long term recording, the recording operation can be terminated by a signal from UPS and the RA2300MKII can be turned off.
※Optional RS232C unit or remote unit is required
High speed (100 mm/s) and high density (80 dot/mm at 25 mm/s) recording is possible. Easily change the division of the waveform record and the width of the recording area, etc.
Layout on recording paper
Event Signal Display
This unit performs arithmetic processing (interval statistic calculation, function calculation, FFT analysis) on the data stored in memory, HDD or SSD and displays the results in table, time axis waveform or frequency formats.
Experiments that required a data recorder for measurement and analyzer for analysis can be done with the Omniace alone.
Flow chart of arithmetic operations and FFT unit functions
Dynamic Waveform Display
The RA has a large 12.1 inch LCD and displays dynamic waveforms.
Easy Operation with Rich Features
Set-up displays with the jog dial which makes input amplifier settings easily understood. Measuring conditions can be modified while monitoring waveforms on the large LCD display. The input amplifier can be automatically tuned by the “auto” function button.
User Selectable Measurement Modes
Users can easily select from five (5) Measurement Modes – Pen Recorder mode for real time strip chart recording, HD Recorder mode for long term recording of data to HDD, X-Y Recorder mode for displaying/recording X-Y correlation of two signals, a Multi Recorder mode captures transients while recording steady-state signals, and a Memory Recorder mode for recording fast events.
Multirecorder
Records steady-state and transient events simultaneously. Chart printing and recording to HDD and Memory can be simultaneously performed in this mode. A steady-state signal can be printed or recorded on the HDD while the system captures high-speed transient events to memory.
Capture Complete Signals with Sample Data and Peak Data
When measuring data with the RA Series, you can select from the recording data format used by most recording devices (sample data) and a format that samples data at high speed and records significant points (peak values). When recording with peak data, you can record high frequency noise regardless of paper feed speed. An example of the sample data and peak data recording formats at 10 ms sampling is shown below.
Sample Data Format
Data is recorded every 10 ms (designated recording speed). This method faithfully records the raw data every 10ms.
Peak Data Format
Data is sampled at the maximum sampling speed over a set recording interval (10 ms in this case) and the maximum and minimum values are recorded. This allows compression of data without losing peak values. Peak data requires twice the recording capacity.
High Speed and High Resolution Recording
High speed and high resolution (80 dots/mm at 25mm/s) recording is available. Customizable waveform division & printing size with paper-feed speed of max 100mm/s.
Useful Functions
Easy search of large data sets.
This function displays a waveform image (one selected channel) of recorded data on a thumbnail bar. It allow users to see whole waveform image easily and to enlarge sections by touch scaling.
Display | 12.1 inch TFT color LCD (1024 x 768) with touch panel |
Channel Number | 16ch (8 slots) + 16 inputs logic (option) |
Memory Capacity | 2MW/ch (32MW when using 1ch) |
Sampling Speed | Max. 1μs (1MSa/s) |
Printer | Printer Head: Thermal recording with thermal head |
Chart Speed: 100mm/s to 1mm/min. | |
Recording Device | HD: 160GB, SSD : 256GB (RA2300MKⅡ-S) |
Applicable to external USB memory, HD and MO drive using USB port | |
Interface | Ethernet (100BASE-T), USB x 2 : standard |
RS-232C : option | |
Measuring Mode | Memory Recorder: Recording high speed phenomenon to memory with trigger |
HD Recorder: Recording input signals directly to internal HD or SSD | |
Pen Recorder: Recording input signals directly on chart paper | |
Multi-recorder: Recording on chart paper, HD and Memory simultaneously | |
X-Y Recorder: Displaying and recording the correlation of 2 signals with X-Y | |
Operation Environment | Temperature 5 to 40℃, Humidity 35 to 80%RH (no condensation) |
Power Supply | 90 to 264V AC, 50 to 60Hz |
Power Consumption | 400VA or less (at maximum load condition) |
Dimensions | W 400 (±2.0) x H 171 (±2.0) x D337 (±2.0) mm with handle folded down |
Input Amplifiers
Item | Model | Description |
2-CH High Resolution DC Amp. | AP11-101 | Input: ±100mV to ±500V, A/D resulution: 16bit, Sampling 10μs |
2-CH FFT Amp. | AP11-102 | Antialiasing filter: 72dB/OCT, with power supply for sensor |
2-CH High Speed DC Amp. | AP11-103 | Input: ±100mV to ±500V, A/D resulution: 12bit, Sampling 1μs |
2-CH AC Strain Amp. *1 | AP11-104A | Frequency characteristic: 2KHz, Bridge voltage: 5KHz |
Event Amp. | AP11-105 | Input: 8 logic (Voltage/Contact) |
2-CH TC/DC Amp. *2 | AP11-106A | Input: R, T, J, K, W (±100mV to ±500V), A/D resolution: 15bit |
2-CH TC/DC Amp. *2 | AP11-107 | Input: R, T, J, K (±100mV to ±50V), A/D resolution: 14bit |
F/V Converter *2 | AP11-108 | Input: 1Hz to 10KHz |
2-CH Vibration/RMS Amp. | AP11-109 | Input: ±100mV to ±500V, Sampling: 10μs, with power supply for sensor |
2-CH DC Strain Amp. | AP11-110 | Input: 800με to 20Kμε (BV=5V), 2Kμε to 50Kμε (BV=2V) |
2-CH Zero Sppression Amp. | AP11-111 | Input: ±100mV to ±500V, A/D resulution: 16bit, Sampling 10μs |
*1: AC bridge power supply (RA23-141) is required.
*2: AP11-106A, AP11-107 and AP11-108 do not comply with RoHS directive of CE.
Item | Model | Description |
Remote Unit | RA23-144 | With cale (0311-5251: 1.5m, I/O connector: 28pin, One side w/o connector |
Event Unit | RA23-145 | Event Unit + Event Cable w/o connector (0311-5252) |
Event Unit A | RA23-145A | Event Unit + Interconnecting cable for event (RA23-127) |
RS-232C Unit | RA23-142 | |
AC Bridge Power Supply Unit | RA23-143 | It is required when using AP11-104A |
Item | Model | Description |
Unifizer | NS3300 | Applicable to Windows 7 (32bit) |
Literature (RA2300MKII/RA2800A)
Our products simultaneously measure voltage, current, control timing, vibration, rotation, pressure and more directly from sensors.
Measure and analyze vibration data for the development and maintenance of railway cars.
Strength test and flaw detection in quality control of steel, concrete and composite materials.
Need help or have questions?
Visit our support center for software downloads, warranty information, customer service, and to contact support.